Rectifiers battery chargers (DC UPS)

Rectifiers battery chargers (DC UPS)

Showing all 7 results

  • Open frame solutions

    Rectifiers Battery chargeron open frame solutions

    Rectifiers Battery charger on open frame solutions

    Tecnical detail

    Rectifiers battery charger on open frame solution.

    • Removable modular technology 
    • Input power transformer
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Easy installation
    • Complete system with front panel and instruments 



    • Removable modular conversion units
    • Terminal blocks for connection cables
    • SPDT alarm board as standard
    • LEDs boards in the front panel  
    • Digital instrument for battery voltage and current



    • Easy to use and install
    • Works with all types of lead and NiCd batteries.
    • Hight reliability in industrial environmental conditions
    • Full compliance with international IEC standards.
    • Front panel with 1.5 meter cable can easily be installed outside the existing cabinet



     

    More info?

    Contact us!

    Applications

    • Replacement of old rectifiers
    • Installation in the compartments of the MV panels


    MORE INFO
  • AMS

    Rectifiers Battery chargerfrom 5 to 40 A, hight frequency Chopper technology, natural cooling

    Rectifiers Battery charger from 5 to 40 A, hight frequency Chopper technology, natural cooling

    Tecnical detail

    Hight frequency battery charger rectifier, natural cooling, to supply the auxiliary in the substation and protection relays

    • Chopper removable modular technology
    • Input insulation power transformer
    • Natural cooling  
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Customizable according to customer specification



    • Easy Removable modular conversion units
    • The batteries can be installed in the bottom of the cabinet
    • Input power transformer
    • Natural cooling of the cabinet and power conversion units
    • MCB Distribution switches installed on the door (optional)
    • Optional analog Instruments
    • Cabinet protection degree up to IP42
    • Can be installed stick to the wall
    • Heavy metal structure of the cabinet
    • Easy transport by Hand pallet trucks
    • Terminal blocks for the connection cables
    • SPDT alarm board as standard
    • LEDs boards to show the main operation mode
    • Digital instrument for battery voltage and current



    • Easy to install
    • Works with all types of batteries lead and NiCd
    • Hight reliability in industrial environmental conditions
    • Full compliance with international IEC standards.



     

    More info?

    Contact us!

    Applications

    • DC auxiliaries of MV, HV substations and protections relay


    MORE INFO
  • ATT

    Battery charger rectifiers, double-branch5 to 60 A, Chopper technology

    Battery charger rectifiers, double-branch, 5 to 60 A, Chopper technology

    Double branch Rectifiers battery charger to supply the auxiliary in the substation and protection relays

    • Output Voltage +/- 1% independent from the battery
    • Chopper removable modular technology
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Emergency exchange system
    • Battery and system branch in chopper technology



    • Removable modular conversion units
    • Input power transformer
    • Natural cooling of the cabinet and conversion units
    • MCB Distribution switches as optional  
    • Optional analog instruments
    • Cabinet Protection degree up to IP42
    • Heavy  metal structure of the cabinet
    • Easy transport by Hand pallet trucks
    • Terminal blocks for connection cables
    • SPDT alarm board as standard
    • LEDs boards in front  
    • Digital instrument for battery voltage and current



    • Easy to use and install
    • Works with all types of lead and NiCd batteries.
    • Hight reliability in unfavourable environmental conditions
    • Full compliance with international IEC standards.



     

    More info?

    Contact us!

    Applications

    • Medium voltage substations auxiliaries
    • protection relays
    • Emergency lighting


    MORE INFO
  • AME

    Rectifiers Battery charger60 to 120 A, SCR technology

    Rectifiers Battery charger, 60 to 120 A, SCR technology

    Tecnical detail

    Rectifiers battery charger to supply the auxiliary in the substation and protection relays

    • SCR removable modular technology
    • Input power transformer
    • Natural cooling of the cabinet  
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Customizable according to customer specification



    • Removable modular conversion units
    • Input power transformer
    • Natural cooling of the cabinet 
    • MCB distribution switches installed on the door (optional)
    • Optional analog instruments
    • Cabinet Protection degree up to IP42
    • Can be installed stick to the wall
    • Heavy metal structure of the cabinet
    • Easy transport by Hand pallet trucks
    • Terminal blocks for connection cables
    • SPDT alarm board as standard
    • LEDs boards for the main operation  visual check
    • Digital instrument for battery voltage and current



    • Easy to use and install
    • Works with all types of lead and NiCd batteries.
    • High reliability in industrial environmental conditions
    • Full compliance with international IEC standards.



     

    More info?

    Contact us!

    Applications

    • DC auxiliaries of MV, HV substations and protections relay


    MORE INFO
  • ATE

    Rectifiers Battery chargerdouble-branch, 60 to 120 A, SCR technology

    Battery charger rectifiers, double-branch, 60 to 120 A, SCR technology

    Tecnical detail

    Double branch Rectifiers battery charger to supply the auxiliary in the substation and protection relays

    • Output Voltage +/- 1% independent from the battery
    • Chopper removable modular technology
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Emergency exchange system
    • Battery branch in chopper technology
    • System branch in SCR technology



    • Removable modular conversion units
    • Input power transformer
    • Natural cooling of the cabinet and conversion units
    • MCB Distribution switches as optional 
    • Optional analog instruments
    • Cabinet Protection degree up to IP42
    • Heavy  metal structure of the cabinet
    • Easy transport by Hand pallet trucks
    • Terminal blocks for connection cables
    • SPDT alarm board as standard
    • LEDs boards in front 
    • Digital instrument for battery voltage and current



    • Easy to use and install
    • Works with all types of lead and NiCd batteries.
    • Hight reliability in unfavourable environmental conditions
    • Full compliance with international IEC standards.



     

    More info?

    Contact us!

    Applications

    • Medium voltage substations auxiliaries
    • protection relays
    • Emergency lighting


    MORE INFO
  • RDC

    Digital rectifiers battery charger60 to 3000 A, SCR technology

    Digital rectifiers battery charger, 60 to 3000 A, SCR technology

    Tecnical detail

    Industrial Heavy duty rectifiers battery charger customizable for application in Power plants or Oil&Gas, heavy critical business

    • 6 pulse or 12 pulse removable modular SCR technology  
    • Input power transformer
    • Natural cooling
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Customizable according to customer specification



    • Input power transformer
    • 6 pulse or 12 pulse SCR technology
    • Conversion unit in removable modular system
    • DSP+PLL control boards
    • Natural cooling  
    • Cabinet Protection degree up to IP54
    • Tropicalization of the electronics boards (optional)
    • MCB or MCCB in input  
    • Five automatic battery charging modes
    • Colour graphic touch screen display
    • Thermal and isolation Class H for power transformers and inductance
    • Heavy cabinet structure
    • Access from the front for maintenance
    • Low MTTR



    • High efficiency
    • Full compliance with international IEC standards.
    • Customizable according the technical specifications of the customers
    • Optional analog instruments, dropping diode
    • Parallel with current sharing.
    • USB port as standard.
    • SPDT cards as standard
    • Terminal blocks for cables connection



     

    More info?

    Contact us!

    Applications

    • Medium voltage substations auxiliaries
    • protection relays
    • Lubrication pumps alternators in the power plants
    • Emergency lighting


    MORE INFO
  • SEE

    Rectifiers Battery charger60 to 400 A, SCR technology

    Rectifiers Battery charger, double-branch, 60 to 400 A, SCR technology

    Double branch Rectifiers battery charger to supply the auxiliary in the substation and protection relays

    • Output Voltage +/- 1% independent from the battery
    • Chopper removable modular technology
    • Industrial output voltages 24, 48, 60, 110, 125, 220Vdc
    • Emergency exchange system
    • Battery and system branch in SCR technology



    • Removable modular conversion units
    • Input power transformer
    • Natural cooling of the cabinet and conversion units
    • MCB Distribution switches as optional 
    • Optional analog instruments
    • Cabinet Protection degree up to IP42
    • Heavy  metal structure of the cabinet
    • Easy transport by Hand pallet trucks
    • Terminal blocks for connection cables
    • SPDT alarm board as standard
    • LEDs boards in front 
    • Digital instrument for battery voltage and current



    • Easy to use and install
    • Works with all types of lead and NiCd batteries.
    • Hight reliability in unfavourable environmental conditions
    • Full compliance with international IEC standards.



     

    More info?

    Contact us!

    Applications

    • Medium voltage substations auxiliaries
    • protection relays
    • Emergency lighting


    MORE INFO
TOP