Customization vs. Standardization in EPC Projects: When a Tailor-Made UPS Reduces Total Plant Costs

11 hours ago
4 min read

In EPC (Engineering, Procurement and Construction) projects, the choice between a standard off-the-shelf industrial UPS and a customized industrial UPS (Engineered to Order) is often made by comparing only the equipment purchase price (CAPEX). In complex facilities—such as Oil & Gas, electrical substations, water treatment plants, heavy industry, or energy infrastructure—this evaluation is incomplete.

The decisive metric for the EPC Contractor and the end client is the plant's TCO (Total Cost of Ownership), which combines equipment cost with detail engineering, civil works, cabling, SCADA/DCS integration, testing (FAT/SAT), and operating expenses (OPEX). In many design scenarios, a tailor-made heavy-duty UPS reduces overall project costs compared to a standard solution adapted on-site.


Why a Standard UPS Can Generate Extra Costs in EPC Projects


A standard unit is designed for average installation conditions. When included in an EPC specification with strict constraints, discrepancies tend to surface after order placement:

  • Mechanical and layout constraints: Dimensions incompatible with existing switchgear rooms, shelters, or prefabricated e-houses; fixed cable entry directions (top-only or bottom-only); or the need for front-only maintenance access. Adapting to these limits requires modifications to structural steelwork, cable ducts, or room layouts.

  • Electrical and supervision integration: Non-standard auxiliary or distribution voltages, an insufficient number of dry contacts, signal mapping misaligned with project specifications, or non-native communication protocols (Modbus RTU/TCP, IEC 61850, Profibus).

  • Harsh environmental conditions and derating: Environments with ambient temperatures exceeding 40–50 °C, conductive or abrasive dust, high humidity, or corrosive atmospheres impose severe derating on standard units, forcing oversizing or additional HVAC capacity.

  • Documentation and testing bottlenecks: Generic technical documentation requiring rework for end-client approval, Factory Acceptance Test (FAT) procedures incomplete relative to the ITP (Inspection and Test Plan), or open punch lists during the Site Acceptance Test (SAT).


Technical and Economic Comparison: Standard vs. Customized UPS


Project Parameter

Standard Off-the-Shelf UPS

Customized UPS (Engineered to Order)

Impact on Plant TCO

Detail engineering & layout

Requires adapting the plant to the equipment

Designed around actual footprint, cable entry, and airflow constraints

Reduces modifications to e-houses, cable trays, steelwork, and cabling

SCADA / DCS interfaces

Limited or reliant on additional external cards

Aligned with specifications (required alarms, measurements, protocols)

Reduces wiring, configuration, and commissioning hours

Environmental resistance

Built for controlled environments; requires derating or extra HVAC

Sized for high temperatures, dust, salinity, and high IP ratings

Avoids unnecessary oversizing and reduces cooling energy consumption

Documentation & FAT

Standard package requiring integration during engineering

Vendor Data Book and FAT aligned with EPC specifications

Accelerates document approvals and reduces SAT risks

Purchase cost (Equipment CAPEX)

Lower per single unit

Higher per single unit

May be higher at order stage, but lower across total plant cost


When to Choose a Tailor-Made UPS in an EPC Project


Customization should not apply to every minor detail, but rather focus on the variables that affect engineering, installation, and operational reliability.


1. Constrained Spaces, E-Houses, and Revamping Projects

In prefabricated modules (e-houses or technical containers) and existing plant retrofits, every centimeter impacts structural and transport costs. Defining exact width, depth, front component access, and top or bottom cable entry eliminates costly mechanical redesigns.


2. Severe Industrial Environments and Extreme Climates


In sectors such as Oil & Gas, petrochemicals, steelmaking, mining, or large-scale projects in the Middle East and North Africa, UPS systems often operate in high ambient temperatures, sand, dust, or chemical agents. A custom design allows for an appropriate IP protection rating, redundant ventilation with dedicated filtration, protective board coating (conformal coating), and components selected to operate without penalizing derating.


3. Specific Electrical Requirements and Continuity Architectures


When specifications call for redundant configurations (N+1, 2N), compatibility with diesel generators, management of non-linear or heavy industrial loads, or integration with DC distribution systems (industrial rectifiers/battery chargers and dedicated battery banks), an engineered design avoids technical compromises.


4. Projects with Commissioning Delay Penalties

In EPC contracts, the cost of a commissioning delay quickly outweighs any savings achieved on a standard component. Aligning electrical schematics, sizing calculations, certifications, and FAT procedures from the outset minimizes unexpected issues during SAT and plant start-up.


Technical Specification Checklist for an EPC Industrial UPS


Before freezing the Material Requisition (MR) or purchase specification, verify these five parameters:

  1. Physical and mechanical constraints: Maximum allowable footprint, cable entry/exit direction, maintenance access side, IP protection rating, and anti-corrosion surface treatment.

  2. Design environmental conditions: Maximum and minimum ambient temperatures, relative humidity, installation altitude, and presence of dust or aggressive gases.

  3. Electrical and load data: Input/output voltage and frequency, load power factor, inrush currents, presence of distorting loads, and required autonomy at battery End of Life (EoL).

  4. Supervision and diagnostics: List of critical and diagnostic signals, dry contacts, network protocols required by the DCS/SCADA, and battery health monitoring.

  5. Documentation and testing: List of deliverables (single-line and functional diagrams, thermal calculations, battery sizing, SPIR spare parts list, O&M manuals) and FAT/SAT requirements.


Lever Srl Engineering Support for EPC Projects


Lever Srl supports engineering firms, panel builders, and EPC Contractors from the early bidding and detail engineering stages in the design and manufacture of heavy-duty industrial UPS systems, rectifiers, and tailor-made uninterruptible power systems. A co-engineering approach optimizes footprint, electrical performance, environmental resilience, and documentation packages, reducing technical risks and total plant costs.



Are you defining the specification for an uninterruptible power system for an industrial or EPC project?

Contact the Lever Srl technical team to evaluate the best solution for your project constraints.